Product Description

CCSi UltraLife molds are designed, engineered, and manufactured to produce high quality specimens, over an extended service life!

CCSi manufactures these specimen molds for the determination of the resistance to abrasion of vulcanized rubber and other materials, most commonly used for the soles, heels, uppers, and other components of footwear where exposure to abrasion is a concern, as described in ASTM D1630 “Standard Test Method for Rubber Property — Abrasion Resistance (Footwear Abrader).”

The subject material is tested under specific conditions. A reference material is tested under identical conditions, and a relative resistance to abrasion of the subject material (abrasive index) is calculated.

This necessitates accurately prepared specimens, from both the reference material and the subject material. Ideally, the specimens are prepared using the CCSi UltraLife specimen mold. However, the test pieces, from which the specimens are obtained, may also be die cut from articles, which may also require that the test piece be buffed or ground.

CCSi manufactures the UltraLife D1630 Cutting Die, features the Emerson Type Rubber Buffer, and the Hung Ta™ Par-Marton Type Specimen Adjuster, all of which are designed for obtaining test pieces and specimens from articles.

Get a Quote or Purchase this Product

Ask for Price

Get Quote
top
CCSi UltraLife Specimen Molds: Quality Manufacturing Fill 118 Copy 1 Created with Sketch.

CCSi UltraLife molds are manufactured from homogenous, solid, high carbon content A2 mold steel. Each undergoes precision grinding and CNC (Computer Numerical Control) machining to exacting requirements. The mold cavities are expertly honed and hand polished, after which the mold is industrial chrome plated.

Precision grinding ensures a parallel surface profile of the platens and CNC machining provides ultra-close dimensional tolerances, while the honing and polishing processes guarantee smooth, true specimen cavities. The durable, hard chrome finish resists the corrosive and adhesive effects of most compounds, greatly improving overall durability and ease of maintenance.

The CCSi UltraLife mold platens are thicker than standard molds, providing superior heat and pressure distribution, as well as extending the mold’s useful life by resisting distortion. This also allows the overflow recesses to be deeper, reducing problems associated overfill. The platens are positively positioned with precision guide pins and receivers … assuring precise closure!

CCSi UltraLife Specimen Molds: Innovative Design Fill 118 Copy 1 Created with Sketch.

CCSi UltraLife molds feature a unique cam-action hinge design which improves the critical distribution of pressure. Typical ‘fixed-hinge’ designs cause material to flow, outwardly, from this constraining point. This uneven application of pressure may cause excessive overfill, or cavity voids. The cam-action hinge design has all of the advantages of ‘stacked plate’ molds, combined with the convenience of ‘fixed-hinge’ designs!

The handles are manufactured from 304 stainless steel (a chromium – nickel austenitic alloy) and contain integral support pins. This allows the handles to rotate, which facilitates opening the mold. The handles are ergonomically positioned to ease placement and removal from the heated laboratory press.

Large triangular pry slots are located at the corners, opposite the cam-action hinges. These further facilitate mold opening and reduce the occurrence of cavity damage from improperly positioned tools.

CCSi UltraLife Specimen Molds: Features Fill 118 Copy 1 Created with Sketch.

The CCSi ASTM D1630 Specimen Molds Feature:

  • Exclusive UltraLife engineering;
  • Designed with advanced 3D solid modeling;
  • Manufactured using computerized systems and techniques;
  • CNC (Computer Numerical Control) 4 axis machining;
  • Precision ground;
  • Expertly honed;
  • Finely polished;
  • High carbon content A2 mold steel;
  • Thicker plates resist warping, distribute heat and pressure evenly;
  • Cam action hinges prevent uneven closure;
  • Industrial chrome plate finish;
  • 304 stainless steel rotating handles ease opening, closing and handling;
  • Deep overflow recesses (flash pockets) reduce overfill problems;
  • Precision locator pins & receivers assure positive alignment;
  • High strength fasteners resist the effects of strain and stress;
  • Temperature probe orifices may be added for profiling;
  • Optional finishes are available for highly corrosive compounds.

Available in:

  • ASTM D1630 UltraLife 9 Cavity Mold.
CCSi UltraLife ASTM D1630 Specimen Molds: Specifications Fill 118 Copy 1 Created with Sketch.
Part Number Mold Configuration Specimen Size
CCS-MD1630-9D1630 9 Cavity, 2 Plate Specimen Mold 25.0 x 25.0 x 6.35 mm (0.984 x 0.984 x 0.25 inch)

Index Terms: Fill 118 Copy 1 Created with Sketch.

molds, test specimen molds, Standard Test Method for Rubber Property – Abrasion Resistance (Footwear Abrader), ASTM D1630, D1630, abrasion resisitance, abrasion, footwear abrader, footwear, abrader, garnet paper, NBS abrader, NBS, sandpaper.