Accredited Laboratory

A2LA has accredited

 

CORPORATE CONSULTING SERVICE & INSTRUMENTS INC.

Akron, OH 
for technical competence in the field of

Calibration

This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This laboratory also meets any additional program requirements in the field of calibration. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009).

Presented this 26th day of February 2020.
(signature)
Senior Director of Quality and Communications
For the Accreditation Council
Certificate Number 1424.01
Valid to November 30, 2021

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CORPORATE CONSULTING, SERVICE, & INSTRUMENTS, INC.

1868 Akron-Peninsula Rd.
Akron, OH 44313
Michael Kent Warner
Phone: 330 376 3600

CALIBRATION

Valid to November 30, 2021
Certificate Number: 1424.01
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations1:
I. Dimensional

II. Mechanical

III. Thermodynamics

IV. Time and Frequency

1 This laboratory offers commercial and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 – General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations. Please note the actual measurement uncertainties achievable on a customer’s site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
4 Calibration is performed according to manufacturer specifications and measure in gram force.
5 In the statement of the CMC, L is the numerical value of the nominal length of the device measured in inches and R is the resolution of the device under test.

(A2LA Cert. No. 1424.01) 02/26/2020

Contact CCSi to request calibration services.