back  request for quotation (rfq) request for information (rfi) Adobe® PDF Document download bookmark this page home
OREC™ 0500 — 0900 Series Ozone Test Chambers: Specifications
model: 0500 0900 0500A 0900A 0500C 0900C
test methods: 1 c · d · g · h
j · i · k · l
a · e · f · g
h · i · j · k · l
a · c · d · g· f
h · i · j · k · l
ozone generator: quartz uv corona discharge quartz uv &
corona discharge
ozone range: 0—250 pphm/vol

0—1000 pphm/vol 2
10—300 ppm/vol 0—250 pphm/vol
10—300 ppm/vol
0—1000 pphm/vol 2
air flow: cfm 0—6 0—15 10—20 10—20 10—20
0—61
10—20
0—15
system accuracy: measurement: 3% of reading      Control: 4% of set—point
temperature: up to 90° C (194º F)
oven chamber: cm
in.
61 x 46 x 51
24 x 18 x 20
76 x 76 x 76
30 x 30 x 30
61 x 46 x 51
24 x 18 x 20
76 x 76 x 76
30 x 30 x 30
61 x 46 x 51
24 x 18 x 20
76 x 76 x 76
30 x 30 x 30
oven chamber: m³
ft³
    0.142
5.0
   0.443
15.625
    0.142
5.0
   0.443
15.625
    0.142
5.0
  0.443
15.625
dimensions: cm
in.
122 x 64 x 84
48 x 25 x 33
137 x 91 x 114
54 x 36 x 45
122 x 64 x 84
48 x 25 x 33
137 x 91 x 114
54 x 36 x 45
122 x 64 x 84
48 x 25 x 33
137 x 91 x 114
54 x 36 x 45
net weight: kg
lb
180
410)
261
580)
273
600)
355
780)
282
620)
364
800
· 1 Test Method References
a) ASTM D470 crosslinked insulations and jackets for wire and cable
b) ASTM D518 rubber deterioration—surface cracking
c) ASTM D1149 rubber deterioration—surface ozone cracking in a chamber
d) ASTM D1171 rubber deterioration—surface ozone cracking outdoors or chamber
e) ASTM D1352 ozone—resisting butyl rubber insulation for wire and cable
f) ASTM D1373 specification for medium-voltage rubber insulating tape: withdrawn in 1986
g) ASTM D3041 testing coated fabrics—ozone cracking in a chamber: replaced by D1149
h) ASTM D3395 rubber deterioration—dynamic ozone cracking in a chamber
i) ASTM D4575 rubber deterioration reference and alternative method(s) for determining ozone level in laboratory test chambers, (method a only)
j) ISO 1431—1: 1989 resistance to ozone cracking — part 1: static strain
k) ISO 1431—2: 1994 resistance to ozone cracking — part 2: dynamic strain test
l) ISO 1431—3: 2000 resistance to ozone cracking — part 3: reference and alternative methods for determining the ozone concentration in laboratory test chambers
· 2 Requires the optional 2nd UV lamp.
NIST Primary Traceability & ISO/IEC 17025 Accredited Laboratory
National Institute of Standards and Technology American Association for Laboratory Accreditation

National Institute of Standards and Technology
Primary Traceability

NIST Report of Analysis 839.03-03-155
NIST Report of Analysis 839.03-05-168

ISO/IEC 17025
Accredited Laboratory

Calibration Certificate 1424.01
Mechanical Testing Certificate 1424.02

Index Terms: OREC, Ozone Research Equipment Company, 0500, 0900, ozone test chambers, ozone, ozone destruction, ozone generation, ozonator, ozone generator, ozone test chamber, ozone monitor, Osmonics, ASTM D518, ASTM D1149, ASTM D1171, ASTM D3395, ASTM D4575, ASTM D470, ISO 1431, ozone research, rubber cracking, ozone resistance, rubber, crack growth, weathering, rubber deterioration, surface cracking, ozone cracking, ozone measurement, rubber test, ultraviolet, UV.
Copyright © 2006 CCSi, Inc. • All Rights Reserved • Published August, 2006
Corporate Consulting, Service & Instruments, Incorporated
221 Beaver Street • Akron, Ohio 44304 USA
Telephone: 800.742.8535 / 330.376.3600 • Facsimile: 800.229.9329 / 330.376.8500
www.ccsi-inc.com www.orecozone.net